Worked Examples To Eurocode 2 Volume 2 -

The provided reinforcement area is:

VEd = 1.35 x (2 x 4 / 2) + 1.5 x (1.5 x 4 / 2) = 18.5 kN worked examples to eurocode 2 volume 2

The slab is checked for punching shear:

λ = 3 / 0.4 = 7.5

As = 0.0013 x 0.2 x 1 x 500 = 130 mm^2